Attic Pull-Down Ladder Mistakes

January 27, 2022
by Charlie Priest
Attic pull-down ladders, also called attic pull-down stairways, are collapsible ladders that are permanently attached to the attic floor. Occupants can use these ladders to access their atticsAttic pull down ladder without being required to carry a portable ladder.

Common Defects

Homeowners, not professional carpenters, usually install attic pull-down ladders. Evidence of this distinction can be observed in consistently shoddy and dangerous work that rarely meets safety standards. Some of the more common defective conditions we see include:

  • Cut bottom cord of structural truss. Often, homeowners will cut through a structural member in the field while installing a pull-down ladder, unknowingly weakening the structure. Structural members should not be modified in the field without an engineer’s approval;
  • Fastened with improper nails or screws. Homeowners often use drywall or deck screws rather than the standard 16d penny nails or ¼” x 3” lag screws. Nails and screws that are intended for other purposes may have reduced shear strength and they may not support pull-down ladders;
  • Fastened with an insufficient number of nails or screws. Manufacturers provide a certain number of nails with instructions that they all be used, and they probably do this for a good reason. Be wary of “place nail here” notices that are nowhere near any nails;
  • Lack of insulation. Hatches in many houses (especially older ones) are not likely to be weather-stripped and/or insulated. An uninsulated attic hatch allows air from the attic to flow freely into the home, which may cause the heating or cooling system to run overtime. An attic hatch cover box can be installed to increase energy savings;
  • Loose mounting bolts. This condition is more often caused by age rather than installation, although improper installation will hasten the loosening process;
  • Attic pull-down ladders are cut too short. Stairs should reach the floor;
  • Attic pull-down ladders are cut too long. This causes pressure at the folding hinge, which can cause breakage;
  • Improper or missing fasteners;
  • Compromised fire barrier when installed in the garage;
  • Attic ladder frame is not properly secured to the ceiling opening;
  • Closed ladder is covered with debris, such as blown insulation or roofing material shed during roof work.
  • Cracked steps. This defect is a problem with wooden ladders.
  • In sliding pull-down ladders, there is a potential for the ladder to slide down quickly without notice. Always pull the ladder down slowly and cautiously.

 Relevant Codes

The 2009 edition of the International Building Code (IBC) and the 2006 edition of the International Residential Code (IRC) offer guidelines regarding attic access, although not specifically pull-down ladders. Still, the information might be of some interest.

2009 IBC (Commercial Construction):

1209.2 Attic Spaces. An opening not less than 20 inches by 30 inches (559 mm by 762 mm) shall be provided to any attic area having a clear height of over 30 inches (762 mm). A 30-inch (762 mm) minimum clear headroom in the attic space shall be provided at or above the access opening. 

2006 IRC (Residential Construction):

R807.1 Attic Access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that exceed 30 square feet (2.8m squared) and have a vertical height of 30 inches (762 mm) or more. The rough-framed opening shall not be less than 22 inches by 30 inches, and shall be located in a hallway or readily accessible location. A 30-inch (762 mm) minimum unobstructed headroom in the attic space shall be provided at some point above the access opening.

Tips:

  • Do not allow children to enter the attic through an attic access. The lanyard attached to the attic stairs should be short enough that children cannot reach it. Parents can also lock the attic ladder so that a key or combination is required to access it.
  • If possible, avoid carrying large loads into the attic. While properly installed stairways may safely support an adult man, they might fail if he is carrying, for instance, a bag full of bowling balls. Such trips can be split up to reduce the weight load.
  • Replace an old, rickety wooden ladder with a new one. Newer aluminum models are often lightweight, sturdy and easy to install.

In summary, attic pull-down ladders are prone to a number of defects, most of which are due to improper installation.

Common Electrical Issues Inspectors Find in Older Homes

Older homes possess a unique charm, often boasting architectural features and character that can be hard to find in modern houses. When it comes to the electrical systems in these older properties, there are several common issues that home inspectors frequently...

Areas That Are Most Affected by Moisture in Your Home

Moisture can be a silent yet destructive force within homes, affecting various areas in ways that are often not immediately apparent. Whether you're a home buyer or a seller, understanding how moisture impacts different sections of a property is crucial. This...

Why Roofs Need to Be Inspected By a Professional

When it comes to buying or selling a home, one crucial aspect that should never be overlooked is the roof. Whether you're a home buyer seeking a new abode or a seller aiming to make your property more appealing, a professional roof inspection is a step you shouldn't...

Signs Your Home Has a Rodent Infestation

Whether you are buying a new home, selling your current one, or just want to ensure the safety of your living environment, spotting a rodent infestation is crucial. Rodents can cause extensive damage to the structure of the house and also pose health risks. Being...

The Role of Electrical Inspections in Your Home

In the intricate web of home maintenance and safety, electrical inspections play a pivotal role in ensuring functionality, preventing hazards, and complying with local regulations. Making sure your electrical systems are working correctly is important to protect your...

Read Also

Let’s Talk About Your Inspection

Send Us an Email

charlie@tninspectionservices.com

Call Us

731-207-0601

Contact Us